ARIET ARIKSO LT33100H

Three-phase UPS ARIKSO LT33H with power rating 10–120 kVA uses online double conversion technology, which makes it possible to completely eliminate all problems associated with the power grid and provide customers with stable and clean sinusoidal power supply.

Application

Description

Three-phase UPS ARIKSO LT33H with power rating 10–120 kVA uses online double conversion technology, which makes it possible to completely eliminate all problems associated with the power grid and provide customers with stable and clean sinusoidal power supply.

The innovative design makes these UPSs exceptionally reliable and ensures high performance.

A high input power factor and minimal input current distortion ensure the UPS’s environmental friendliness and safety, while high efficiency contributes to effective energy savings.

Technical Specifications - LT3310-120H datasheet_En

MODEL LT33100H
SERIES ARIKSO LT33H
Power 100 kVA
Input
Phase 3-phase, 4-wire + ground
Rated Voltage 380/400/415 V AC
Input Voltage Range 138–485 V AC
Grid Frequency Range 40–70 Hz
Power Factor ≥0.99
THDI Input Current Total Harmonic Distortion Factor ≤3% (at 100% non-linear load)
Bypass Voltage Range Maximum voltage: 220 V +25% (options +10% / +15% / +20%); 230 V +20% (options +10% / +15%); 240 V +15% (option +10%);
Minimum voltage: down to -45% (options -10% / -20% / -30%);
Frequency protection: ±10%;
Generator input Supported
Output
Phase 3-phase, 4-wire + ground
Output voltage 380/400/415 V AC
Power Factor 0,9
Voltage stabilization ±1%
Output frequency Grid mode: ±1% / ±2% / ±4% / ±5% (±10% optional)
Battery mode: (50/60 ±0.1) Hz
Crest factor 3:1
THD (output voltage distortion) ≤2% with linear load, ≤4% with non-linear load
Efficiency 95,50%
Overload capability Load ≤110% — 60 minutes, ≤125% — 10 minutes, ≤150% — 1 minute, 150% — switch to bypass
Battery
Voltage ±180 V/192 V/±204 V/±216 V/±228 V/240 V/±252 V/±264 V/±276 V/±288 V/±300 V DC (30/32/34/36/38 V/40/42/44/46/48 V/50 pcs option)
Charge current 30A Max
Switching Time Network → Battery: 0 ms, Network → Bypass: 0 ms
Operating Conditions
Operating Temperature 0~40°C
Storage Temperature -25~55 °C (without batteries)
Humidity 0~95% (non-condensing)
Noise Level <60 dB
Installation Height < 1500 m
Protection
Alarm overload, grid deviation, UPS failure, low battery charge, etc.
Protection short circuit, overload, overheating, low battery charge, fan failure
Interfaces USB, CAN, RS485, FE, LBS, parallel card, relay card, SNMP card (option)
Physical parameters
Dimensions (W*D*H) mm 885*440*1200
Weight (kg) 160
Standards EN62040-1, EN62040-2
  1. Office and Server Equipment
  2. Medical facilities and laboratories
  3. Telecommunications Systems
Преимущества
A wide input voltage range allows the equipment to operate stably even under severe sags and fluctuations in the power grid. This ensures reliable protection of the connected load under unstable power supply conditions.
The use of a DSP processor ensures precise control of all operating modes and a fast system response to load changes. As a result, operational stability and overall equipment reliability are improved.
A convenient interface makes device control simple and understandable even for an untrained user. All key parameters and settings are quickly accessible and displayed in a clear form.
An intelligent battery management system controls charging and discharging, preventing overloads and deep discharge. This extends battery life and improves their readiness for operation during a power outage.
N+X redundancy increases system reliability by adding backup modules that automatically compensate for the failure of any working module.
The presence of RS485 interfaces, a relay card, USB, and an SNMP option ensures convenient monitoring and integration of the UPS into dispatching and remote control systems.
Advantages
A wide input voltage range allows the equipment to operate stably even under severe sags and fluctuations in the power grid. This ensures reliable protection of the connected load under unstable power supply conditions.
The use of a DSP processor ensures precise control of all operating modes and a fast system response to load changes. As a result, operational stability and overall equipment reliability are improved.
A convenient interface makes device control simple and understandable even for an untrained user. All key parameters and settings are quickly accessible and displayed in a clear form.
An intelligent battery management system controls charging and discharging, preventing overloads and deep discharge. This extends battery life and improves their readiness for operation during a power outage.
N+X redundancy increases system reliability by adding backup modules that automatically compensate for the failure of any working module.
The presence of RS485 interfaces, a relay card, USB, and an SNMP option ensures convenient monitoring and integration of the UPS into dispatching and remote control systems.