ARIET ARIKSO LT33400

Three-phase UPS ARIKSO LT33 with online double conversion technology provides stable and clean power supply, completely eliminating the influence of interference and grid instability.

SKU: ARIKSO LT3360H-1 Categories: , Series:
Application

Description

Three-phase UPS ARIKSO LT33 with online double conversion technology provides stable and clean power supply, completely eliminating the influence of interference and grid instability.

The innovative design makes these UPSs exceptionally reliable and ensures high performance.

A high input power factor and minimal input current distortion ensure the UPS‘s environmental friendliness and safety, while high efficiency contributes to effective energy savings.

Technical Specifications - LT33400 datasheet_En

MODEL ARIKSO LT33400
Capacity 400 kVA
Input
Phase 3 phases, 4 wires + ground
Nominal voltage 380/400/415 VAC
Input voltage range 138–485 VAC
Mains frequency range 40-70 Hz
Power factor ≥0.99
THDi (Total harmonic distortion of input current) ≤3% (at 100% linear load), ≤5% (at 100% non-linear load)
Bypass voltage range Maximum voltage: 220 V +25% (options +10% / +15% / +20%); 230 V +20% (options +10% / +15%); 240 V +15% (option +10%). Minimum voltage: -45% (optional -10%, -20%, -30%). Minimum voltage: up to -45% (options -10% / -20% / -30%). Frequency protection: ±10%
Generator input Supported
Output
Phase 3 phases, 4 wires + ground
Output voltage 380/400/415 VAC
Power factor 0.9
Voltage regulation ±1%
Output frequency Mains mode: ±1% / ±2% / ±4% / ±5% (±10% of nominal frequency — optional); Battery mode: (50/60 ±0.1) Hz
Crest factor 3:1
THD (Total harmonic distortion of output voltage) ≤2% with linear load, ≤4% with non-linear load
Efficiency ≥ 96%
Overload capacity Load ≤110% — 60 minutes, ≤125% — 10 minutes, ≤150% — 1 minute, >150% — transfer to bypass
Battery
Voltage ±180 V / 192 V / ±204 V / ±216 V / ±228 V / 240 V / ±252 V / ±264 V / ±276 V / ±288 V / ±300 VDC (30/32/34/36/38/40/42/44/46/48/50 pcs, optional)
Transfer time Mains → battery: 0 ms, Mains → bypass: 0 ms
Operating Conditions
Operating temperature 0~40°C
Storage temperature -25~55 °C (without batteries)
Humidity 0~95% (non-condensing)
Noise level <70 dB
Installation altitude < 1500 m
Protection
Alarm overload, mains abnormal, UPS fault, low battery, etc.
Protection short circuit, overload, overtemperature, low battery, fan fault
Interfaces USB, CAN, RS485, FE, parallel card, dry contacts card, SNMP card (optional), LBS (optional), temperature sensor (optional)
Physical Parameters
Dimensions (WDH) mm 850*1200*2000
Weight (kg) 638
Standards EN62040-1, EN62040-2, EN62040-3
  1. Data centers
  2. Financial systems
  3. Telecommunications system
Advantages
A wide input voltage range allows the equipment to operate stably even under severe sags and fluctuations in the power grid. This ensures reliable protection of the connected load under unstable power supply conditions.
The use of a DSP processor ensures precise control of all operating modes and a fast system response to load changes. As a result, operational stability and overall equipment reliability are improved.
A convenient interface makes device control simple and understandable even for an untrained user. All key parameters and settings are quickly accessible and displayed in a clear form.
An intelligent battery management system controls charging and discharging, preventing overloads and deep discharge. This extends battery life and improves their readiness for operation during a power outage.
N+X redundancy increases system reliability by adding backup modules that automatically compensate for the failure of any working module.
The presence of RS485 interfaces, a relay card, USB, and an SNMP option ensures convenient monitoring and integration of the UPS into dispatching and remote control systems.