ARIET ABELLION M331200 Module 100 kVA

The newest generation of centralized bypass three-phase input/output modular UPS.

SKU: ABELLION M331200/100 Categories: , Series:
Application

Description

The newest generation of centralized bypass three-phase input/output modular UPS.

The product adopts digital control, modular design, and N+X parallel redundancy technology. Its capacity range covers all power ratings from 100 kVA to 1200 kVA, allowing users to configure the system flexibly and expand investment gradually. Up to 4 units can be connected in parallel for a total capacity of 4800 kVA.

Optional cabinet color customization is available, including: BLACK, WHITE, ORANGE.

Technical Specifications - ARIET Abellion M33 1000-1200 datasheet_En

MODEL M331200
Capacity
Cabinet 100~1200kVA
Module 100 kVA
Max. Module Number 12
Input
Main Input
Rated Voltage 380/400/415Vac
Voltage Range 138~485Vac
Phase 3 Phase 5 Wires
Frequency Range 40-70Hz
Power factor ≥0.99
Current THDi ≤3% (100% linear load); ≤5% (100% non-linear load)
Input power factor ≥0.99
Bypass Input
Rated Voltage 380/400/415Vac
Phase 3 Phase 5 Wires
Bypass Protection ±10%
Power Walking In Yes
Bypass Back Irrigation Yes
Generator Access Yes
Output
Voltage 380/400/415Vac±1%
Power factor 1
Frequency(Hz)
Utility Mode Bypass Protection(inverter supply)
Battery Mode (50/60±0.05%) Hz
Wave Form Pure Sine Wave
Crest Factor 3:1
THD ≤1% (100% linear load);≤3% (100% non linear load)
Transfer Time (ms) Utility to Bypass:0ms; Utility to Battery:0ms
Effieiency(%) ≥96%
Overload ≤110%, to bypass after 60mins; ≤125%, to bypass after 10 mins; ≤150%, to bypass after 1min
Battery
Modular Charge Current Default 20A, max30A.
Voltage Optional Voltage: 360-600Vdc(30~50 pieces optional,no battery N line)
Environment
Operating Temperature 0℃~40℃
Storage Temperature -40℃~70℃(no battery)
Humidity 0~95%(no condensing)
Altitude < 1500m(over 1500m, derating use)
Noise (dB) (1mdistance) <70 dB
Others
Alarm 0verload,utility abnormal,UPS fault, battery low,etc
Protection short circuit, overload, over temperature, battery low, fan falut alarm, bypass back irrigation, lightning protection.
Communication Interface USB, CAN, RS485, FE, Parallel card, Dry contact card, SNMP card (optional), LBS (optional), temperature sensor (optional)
Physical
Dimension (D*W*H) (mm)
Cabinet 1000*1600*2000(1 switch) / 1000*1800*2000(4 switches)
Module 750*440*131
Net Weight (kg)
Cabinet 720/920
Module 49
Standards EN62040-1, EN62040-2,EN62040-3
  1. Data Centers
  2. Construction organizations
  3. Industrial Enterprises
  4. Financial Systems
Advantages
Advanced Technology DSP control technology, excellent performance, high stability system Three phase Vienna and three-level technology with more than 96% efficiency Output power factor 1.0
High reliability Centralized control redundancy, N+X parallel redundancy up to 99.999% Centralized bypass improves the power supply ability With ЕРО and REPO function
Strong Convenience Modular design, adjustaЫe power module quantity Hot-swappabe module, short maintenance time 10 inches color touch screen, providing abundant UPS status
Smart Design Charging mode in smooth switching bу LCD setting lntelligent charging makes fast charging and extends battery life Multiple optional parts, such as SNMP, relay, dry contact card, etc
Green Concept ЗU modular design saves machine room’s space Parallel shared battery technology reduces battery investment Optional 30-50pcs batteries without N line leads flexibe configuration