ARIET ARIKSO LT33200H

Three-phase UPS ARIKSO LT33H with power rating 200kVA uses online double conversion technology, which makes it possible to completely eliminate all problems associated with the power grid and provide customers with stable and clean sinusoidal power supply.

Application

Description

Three-phase UPS ARIKSO LT33H with power rating 200kVA uses online double conversion technology, which makes it possible to completely eliminate all problems associated with the power grid and provide customers with stable and clean sinusoidal power supply.

The innovative design makes these UPSs exceptionally reliable and ensures high performance.

A high input power factor and minimal input current distortion ensure the UPS’s environmental friendliness and safety, while high efficiency contributes to effective energy savings.

Technical Specifications - LT33200H datasheet_En

MODEL LT33200H
Power 200 kVA
Input
Phase 3 Phase 4 Wires and Ground
Rated Voltage 380/400/415Vac
Operating voltage range 138-485Vac
Operating frequency range 40–70 Hz
Power factor ≥0,99
Harmonic distortion (THDi) <3% (100% non-linear load)
Bypass voltage range Max.voltage: 220Vac +25% (optional +10%,+15%,+20%); 230Vac: +20%(optional +10%,+15%);
240Vac: +15% (optional +10%)
Min. voltage:-45% (optional -10%, -20%,-30%)
Frequency protection range: ± 10%
Generator input Support
Output
Phase 3 Phase 4 Wires and Ground
Output voltage 380/400/415Vac
Power factor 0,9
Voltage regulation ±1%
Output frequency Utility Mode: ±1%/±2%/±4%/ ±5% ± 10% optional;
Battery Mode: (50/60 ±0.1%)Hz
Crest factor 3:1
THD <2% with linear load; ≤4% with non linear load
Efficiency 95,50%
Overload Load≤110%, last 60min; ≤125%, last 10min; ≤150%, last 1min; >150% change to bypass
Battery
Voltage ±180V/192V/±204V/±216V/±228V/±240/ ± 252/±264/±276/±288 /
±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional)
Charge Current 45A Max.
Transfer Time Utility to Battery: Oms; Utility to bypass: Oms
Environment
Operating temperature 0~40°C
Storage temperature -25°C ~ 55°C(no battery)
Humidity range 0~95% (non condensing)
Noise level <65 dB
Altitude < 1500 m
Protection
Alarm overload, utility abnormal, UPS fault, battery low, etc
Protection short circuit, overload, over temperature, battery low, fan fault alarm
Communication USB, CAN, RS485, FE, LBS, Parallel card, Relay card, SNMP card(optional)
Physical
Dimensions D*W*H(mm) 885*440*1200
Net weight (kg) 200
Standards EN62040-1, EN62040-2
  1. Data centers
  2. Financial systems
  3. Security videos urveillance systems
Преимущества
A wide input voltage range allows the equipment to operate stably even under severe sags and fluctuations in the power grid. This ensures reliable protection of the connected load under unstable power supply conditions.
The use of a DSP processor ensures precise control of all operating modes and a fast system response to load changes. As a result, operational stability and overall equipment reliability are improved.
A convenient interface makes device control simple and understandable even for an untrained user. All key parameters and settings are quickly accessible and displayed in a clear form.
An intelligent battery management system controls charging and discharging, preventing overloads and deep discharge. This extends battery life and improves their readiness for operation during a power outage.
N+X redundancy increases system reliability by adding backup modules that automatically compensate for the failure of any working module.
The presence of RS485 interfaces, a relay card, USB, and an SNMP option ensures convenient monitoring and integration of the UPS into dispatching and remote control systems.
Advantages
A wide input voltage range allows the equipment to operate stably even under severe sags and fluctuations in the power grid. This ensures reliable protection of the connected load under unstable power supply conditions.
The use of a DSP processor ensures precise control of all operating modes and a fast system response to load changes. As a result, operational stability and overall equipment reliability are improved.
A convenient interface makes device control simple and understandable even for an untrained user. All key parameters and settings are quickly accessible and displayed in a clear form.
An intelligent battery management system controls charging and discharging, preventing overloads and deep discharge. This extends battery life and improves their readiness for operation during a power outage.
N+X redundancy increases system reliability by adding backup modules that automatically compensate for the failure of any working module.
The presence of RS485 interfaces, a relay card, USB, and an SNMP option ensures convenient monitoring and integration of the UPS into dispatching and remote control systems.