High-quality products at affordable prices, direct from the manufacturer

ARIET ARIKSO LT3320HR

The ARIKSO LT33 is designed for installation in standard 19-inch network cabinets.

SKU: ARIKSO LT3320HR Categories: , Series:
Application

Description

The ARIKSO LT33 is designed for installation in standard 19-inch network cabinets.

The device is built using online double-conversion technology, which effectively eliminates typical power supply quality disturbances and provides consumers with stable power with a pure sine wave.

Technical Specifications - LT3320HR_datasheet_En.pdf

MODEL LT3320HR
Power 20 kVA
Input
Phase 3 phases, 4 wires + grounding
Nominal Voltage 380 / 400 / 415 V AC
Input Voltage Range 138 ~ 476 V AC
Frequency Range 40 ~ 70 Hz
Power Factor ≥ 0.99
Harmonic Distortion (THDi) ≤ 3 % (100 % nonlinear load)
Bypass Voltage Range Max.: 220 V +25 % (opt. +10 %, +15 %, +20 %); 230 V +20 %; 240 V +15 % /
Min.: −45 % (opt. −10 %, −20 %, −30 %); Frequency protection: ±10 %
Input from generator Supported
Output
Phase 3 phases, 4 wires + grounding
Output voltage 380 / 400 / 415 V AC
Power Factor 0.9
Voltage stabilization ±1 %
Frequency Mains: ±1 / ±2 / ±4 / ±5 / ±10 % (optional); Battery: 50 / 60 Hz ±0.1 %
Amplitude ratio 3 : 1
THD (Total Harmonic Distortion) ≤ 2 % (linear load); ≤ 4 % (non-linear load)
Efficiency ≥ 96 %
Overload ≤110% — 60 min; ≤125% — 10 min; ≤150% — 1 min; >150% — transfer to bypass
Battery
Voltage ±180 / 192 / 204 / 216 / 228 / 240 / 252 / 264 / 276 / 288 / 300 V DC current (30 / 32 / 34 /
Charging current Max. 10 A
Switching
Switching time Mains → battery: 0 ms; Mains → bypass: 0 ms
Operating conditions
Operating temperature 0 ~ 40 °C
Storage Temperature −25 ~ 55 °C (without batteries)
Relative Humidity 0 ~ 95 % (non-condensing)
Installation Altitude < 1500 m
Noise Level < 55 dB
Protection
Alarms Overload, mains deviations, UPS fault, low battery charge, etc.
Protection Short circuit, overload, overheating, low battery charge, fan failure
Communications USB, CAN, RS485, FE, LBS, parallel operation card, relay card, SNMP (optional)
Physical Parameters
Dimensions (L×W×H), mm 728*485*130
Weight, kg 25
  1. Office and Server Equipment
  2. Medical facilities and laboratories
  3. Telecommunications Systems
Advantages
Wide input voltage range adapt to harsh power grid
DSP technology greatly improve the system reliability. Real-time protection: DSP processors react instantly to overloads.
Friendly man-machine interface, easy to operate
Intelligent battery management — optimizes charge/discharge modes and extends battery life.