ARIET ARIKSO LT3380H

Three-phase UPS ARIKSO LT33H with power rating 10–120 kVA uses online double conversion technology, which makes it possible to completely eliminate all problems associated with the power grid and provide customers with stable and clean sinusoidal power supply.

Application

Description

Three-phase UPS ARIKSO LT33H with power rating 10–120 kVA uses online double conversion technology, which makes it possible to completely eliminate all problems associated with the power grid and provide customers with stable and clean sinusoidal power supply.

The innovative design makes these UPSs exceptionally reliable and ensures high performance.

A high input power factor and minimal input current distortion ensure the UPS‘s environmental friendliness and safety, while high efficiency contributes to effective energy savings.

Technical Specifications - LT3310-120H datasheet_En

MODEL LT3310H LT3315H LT3320H LT3330H LT3340H LT3360H LT3380H LT33100H LT33120H
Capacity 10 kVA 15 kVA 20 kVA 30 kVA 40 kVA 60 kVA 80 kVA 100 kVA 120 kVA
Input
Phase 3 phases, 4 wires + ground
Nominal voltage 380/400/415 VAC
Input voltage range 138-485 VAC
Input frequency range 40-70 Hz
Power factor ≥0.99
THDi Input current harmonic distortion ≤3% (at 100% non-linear load)
Bypass voltage range Max voltage: 220V +25% (options +10% / +15% / +20%); 230V +20% (options +10% / +15%); 240V +15% (option +10%) Min voltage: up to -45% (options -10% / -20% / -30%) Frequency protection: ±10%
Generator input Supported
Output
Phase 3 phases, 4 wires + ground
Output voltage 380/400/415 VAC
Power factor 0.9
Voltage regulation ±1%
Output frequency Line mode: ±1% / ±2% / ±4% / ±5% (±10% optional) Battery mode: (50/60 ±0.1) Hz
Crest factor 3:1
THD (Output voltage distortion) ≤2% with linear load, ≤4% with non-linear load
Efficiency 95.5%
Overload capacity Load ≤110% — 60 min, ≤125% — 10 min, ≤150% — 1 min, >150% — transfer to bypass
Battery
Voltage Long block: 30-50 pcs; standard block: 30-40 pcs, default: 32 pcs. Long block: 30-50 pcs; standard block: 40-64 pcs, default: 64 pcs. ±180 V/±192 V/±204 V/±216 V/±228 V/±240 V/±252 V/±264 V/±276 V/±288 V / ±300 VDC (30/32/34/36/38/40/42/44/46/48/50 pcs option)
Charge current 10A Max. 15A Max. 30A Max.
Transfer time Utility -> battery: 0 ms, Utility -> bypass: 0 ms
Environment
Operating temperature 0~40°C
Storage temperature -25~55 °C (without batteries)
Humidity 0~95% (non-condensing)
Noise level <55 dB <58 dB <60 dB
Operating altitude < 1500 m
Protection
Alarm overload, utility deviation, UPS failure, low battery, etc.
Protection short circuit, overload, over-temperature, low battery, fan failure
Interfaces USB, CAN, RS485, FE, LBS, parallel card, relay card, SNMP card (option)
Physical parameters
Dimensions (WDH) mm 720*250*535 868*250*862 885*440*1200
Weight (kg) 32 32.5 33 35 38 70.5 150 160 162
Standards EN62040-1, EN62040-2
  1. Data centers
  2. Financial systems
  3. Security video s urveillance systems
Преимущества
A wide input voltage range allows the equipment to operate stably even under severe sags and fluctuations in the power grid. This ensures reliable protection of the connected load under unstable power supply conditions.
The use of a DSP processor ensures precise control of all operating modes and a fast system response to load changes. As a result, operational stability and overall equipment reliability are improved.
A convenient interface makes device control simple and understandable even for an untrained user. All key parameters and settings are quickly accessible and displayed in a clear form.
An intelligent battery management system controls charging and discharging, preventing overloads and deep discharge. This extends battery life and improves their readiness for operation during a power outage.
N+X redundancy increases system reliability by adding backup modules that automatically compensate for the failure of any working module.
The presence of RS485 interfaces, a relay card, USB, and an SNMP option ensures convenient monitoring and integration of the UPS into dispatching and remote control systems.
Advantages
A wide input voltage range allows the equipment to operate stably even under severe sags and fluctuations in the power grid. This ensures reliable protection of the connected load under unstable power supply conditions.
The use of a DSP processor ensures precise control of all operating modes and a fast system response to load changes. As a result, operational stability and overall equipment reliability are improved.
A convenient interface makes device control simple and understandable even for an untrained user. All key parameters and settings are quickly accessible and displayed in a clear form.
An intelligent battery management system controls charging and discharging, preventing overloads and deep discharge. This extends battery life and improves their readiness for operation during a power outage.
N+X redundancy increases system reliability by adding backup modules that automatically compensate for the failure of any working module.
The presence of RS485 interfaces, a relay card, USB, and an SNMP option ensures convenient monitoring and integration of the UPS into dispatching and remote control systems.