High-quality products at affordable prices, direct from the manufacturer

ARIET T6KRS New

The T6-10KRS New series UPS is designed to ensure stable operation thanks to an advanced battery management system.

Application

Description

The T6-10KRS New series UPS is designed to ensure stable operation thanks to an advanced battery management system.

Rated at 240 VDC, the UPS is equipped with high-capacity batteries, ensuring extended runtime during power outages.

A digital charging circuit regulates the charging current from 1 A to 12 A, optimizing battery life and charging efficiency.

Furthermore, the cold battery start feature allows the UPS to start and maintain loads even without a power connection, providing critical backup power in emergency situations.

Technical Specifications - ARIET T6-10KRS New datasheet_En

Parameter Technical Specifications
MODEL T6KRS New
Capacity 6 kVA / 6 kW
Input
Nominal voltage 208/220/230/240 VAC, L+N+PE
Voltage range 110~300 VAC
Frequency range 50/60±6 Hz
Power factor ≥0.99
THDI ≤5% (linear load); ≤8% (non-linear load)
Output
Nominal voltage 208/220/230/240 VAC, L+N+PE
Voltage accuracy ±1%
Frequency 50/60 Hz ± 0.1%
THDu ≤2% (linear load); ≤5% (non-linear load)
Transfer time Zero
Waveform Pure sine wave
Crest factor 3:1
Overload capacity (Line mode) 102%~105% load, 30 min; 105%~125% load, 10 min; 125%–150% load, 30 s; >150% load, 500 ms
Overload capacity (Battery mode) 102%~105% load, 10 min; 105%~125% load, 1 min; 125%–150% load, 10 s; >150% load, 500 ms
Efficiency
Line mode 95%
Battery mode 94.50%
ECO mode 98%
Battery
Nominal voltage 192 VDC (optional 240 VDC)
Battery quantity 9Ah16 pcs. (optional 9Ah20 pcs.)
Charge current 1A(1-12A)
Interface RS232 / USB / SNMP card / AS400 card (optional) / RS485 card (optional) / parallel port (optional)
Operating Conditions
Operating temperature 0~40°C
Humidity 0–95% (non-condensing)
Noise ≤50 dB at 1 meter distance
Installation altitude < 1000 m without derating
Physical Parameters
Dimensions (WDH) mm 440*711*173
Weight (kg) 70
  1. Office and Server Equipment
  2. Medical facilities and laboratories
  3. Telecommunications Systems

① RS232
② Smart Slot
③ USB
④ Input Switch
⑤ Automatic Switch
for maintenance
⑥ Terminal Block
⑦ Output Switch
⑧ EPO (Emergency Power Off)
⑨ Parallel port
⑩ Battery switch
⑪ External battery connection port
⑫ Output connector
⑬ Automatic output
overcurrent protection switch
⑭ Maintenance status

 

Преимущества
The UPS adapts to different areas applications — from small offices to large industrial facilities — thanks to the flexible architecture and a wide range of input voltage.
High output power factor 1 (kVA/kW) allows for efficient power a wide range of loads without loss rated power and overspending network resources.
Compatibility with generators and resistance to unstable power grids make UPS a reliable solution for regions with poor quality of power supply.
Increased security is provided by the emergency function ePO shutdown and automatic protection against output overcurrent.
Modular design and expandable capacity batteries make it easy to scale and upgrade the system as the business grows.
Integration with modern systems monitoring and professional technical support guarantees high reliability and uninterrupted operation of the UPS in the long term perspective.
Advantages
The UPS adapts to different areas applications — from small offices to large industrial facilities — thanks to the flexible architecture and a wide range of input voltage.
High output power factor 1 (kVA/kW) allows for efficient power a wide range of loads without loss rated power and overspending network resources.
Compatibility with generators and resistance to unstable power grids make UPS a reliable solution for regions with poor quality of power supply.
Increased security is provided by the emergency function ePO shutdown and automatic protection against output overcurrent.
Modular design and expandable capacity batteries make it easy to scale and upgrade the system as the business grows.
Integration with modern systems monitoring and professional technical support guarantees high reliability and uninterrupted operation of the UPS in the long term perspective.