High-quality products at affordable prices, direct from the manufacturer

ARIET T6KRS ULTRA

The T6-10KRS ULTRA series online UPS with double conversion is a versatile solution that can be installed in either a 19-inch rack or as a floor-standing unit.

Application

Description

The T6-10KRS ULTRA series online UPS with double voltage conversion is a universal solution that can be installed in either a 19’’ rack or a floor-standing version.

The device provides a high power factor of 1 (kVA = kW) and reliable protection for connected equipment thanks to modern control technologies and a wide range of network input parameters.

High energy efficiency of up to 96% (up to 98% in ECO mode) significantly reduces operating costs while maintaining maximum power reliability.

The 3.5″ color touchscreen LCD display with a user-friendly control panel provides simple and intuitive navigation thanks to interactive icons and informative LED status indicators.

A built-in orientation sensor automatically rotates the screen image depending on the UPS‘s position (rack or tower), ensuring convenient control and ease of use.

Technical Specifications - ARIET T6-10KRS ULTRA datasheet_En

Parameter T6KRS ULTRA T10KRS ULTRA
MODEL T6KRS ULTRA T10KRS ULTRA
Capacity 6 kVA / 6 kW 10 kVA / 10 kW
Input
Input voltage 1 phase 230V (Configurable via display 210V, 220V, 230V) 1 phase 230V (Configurable via display 210V, 220V, 230V)
Voltage range 110–300 V AC 110–300 V AC
Frequency range 50/60 Hz +/- 5% auto-sensing 50/60 Hz +/- 5% auto-sensing
Power factor >= 0.99 >= 0.99
THDi (Total Harmonic Distortion of current) <= 5% <= 5%
Input voltage range at full load 176V – 280V 176V – 280V
Output
Output voltage 230V +/- 1% 230V +/- 1%
Voltage accuracy +/- 1% +/- 1%
Output frequency (nominal) 50/60 Hz (Configurable via LCD panel) +/- 0.1% 50/60 Hz (Configurable via LCD panel) +/- 0.1%
THDu (Total Harmonic Distortion of voltage) < 3% with linear load < 3% with linear load
Transfer time Zero Zero
Waveform Pure sine wave Pure sine wave
Crest factor 3:1 3:1
Built-in automatic bypass Yes Yes
External service bypass Yes Yes
Efficiency
AC/AC up to 96% up to 96%
ECO mode up to 98% up to 98%
Battery
Nominal voltage 240 V DC 240 V DC
Battery quantity 5Ah * 20 pcs. 9.2Ah * 20 pcs.
Battery runtime extension Yes Yes
Automatic detection of battery cabinets Yes Yes
Communication and Management
Screen and signal transmission 3.5" touchscreen display with status indicator bar 3.5" touchscreen display with status indicator bar
Remote control Optional Optional
Communication ports ROO, USB, RS232, SNMP RFC1628 (optional WiFi SNMP) ROO, USB, RS232, SNMP RFC1628 (optional WiFi SNMP)
Backfeed protection Yes Yes
Emergency Power Off (EPO) Yes Yes
Dry contacts Yes, built-in Yes, built-in
Parallel mode Yes Yes
Operating Conditions
Operating temperature 0–40°C 0–40°C
Humidity 0–95% (non-condensing) 0–95% (non-condensing)
Noise level <= 50 dB at 1 meter distance <= 50 dB at 1 meter distance
Protection index IP20 IP20
Physical Parameters
Dimensions (WDH) mm 440 * 176 (4u) * 700 440 * 176 (4u) * 700
Weight (kg) 54 74
Certification EN 62040-1, EN 62040-2, EN 62040-3 EN 62040-1, EN 62040-2, EN 62040-3
  1. Office and Server Equipment
  2. Medical Facilities and Laboratories
  3. Telecommunications Systems

Преимущества
An external manual bypass ensures uninterrupted operation of the critical load during maintenance and testing or in the event of a UPS failure.
A high output power factor 1 (kVA/kW) allows for efficient power supply to a wide range of loads without losing rated power or overusing grid resources.
High efficiency of up to 96% reduces energy consumption and heat generation of equipment.
ECO mode with efficiency of up to 98% reduces operating costs and increases the system’s energy efficiency.
Support for parallel operation of multiple UPSs increases fault tolerance and scalability of the system.
Lithium battery compatibility ensures longer life and configuration flexibility.
Intelligent communication interfaces and SNMP management allow the UPS to be integrated into remote monitoring and control systems.
Enhanced safety is provided by the EPO emergency shutdown function and automatic output overcurrent protection.
Advantages
An external manual bypass ensures uninterrupted operation of the critical load during maintenance and testing or in the event of a UPS failure.
A high output power factor 1 (kVA/kW) allows for efficient power supply to a wide range of loads without losing rated power or overusing grid resources.
High efficiency of up to 96% reduces energy consumption and heat generation of equipment.
ECO mode with efficiency of up to 98% reduces operating costs and increases the system’s energy efficiency.
Support for parallel operation of multiple UPSs increases fault tolerance and scalability of the system.
Lithium battery compatibility ensures longer life and configuration flexibility.
Intelligent communication interfaces and SNMP management allow the UPS to be integrated into remote monitoring and control systems.
Enhanced safety is provided by the EPO emergency shutdown function and automatic output overcurrent protection.